Antistatic 4-Loop big bags — reduce the risk of electrostatic ignitions

The antistatic bags are classified and described as below

Type B

For certain flammable products when not filled or discharged in an explosive gas or vapor atmosphere, we need Type-B bags. It can prevent propagating discharge. Type B bags have a thin coating which results in a breakdown voltage of less than 6 kV .



Type C

For certain flammable products and in the presence of flammable gases or vapors with ignition energies ≥ 0,14 mJ, we need Type-C bags. It is Grounded during filling and discharging to safely dissipate static electricity. Type C bags have an interconnected grid of conductive threads and grounding tabs. 



Type D

For certain flammable products and in the presence of flammable gases or vapors with ignition energies ≥ 0,14 mJ, we need Type-D bags. This Static charges are dissipated by the corona effect, and grounding of the FIBC is not necessary. Type D bags have antistatic fabric with permanent dissipative threads.



Instruction To Use our Antistatic big bag

Bulk Product:
MIE (Minimum Ignition Energy) of Dust

FIBC Type for Different Surroundings

Non-flammable Atmosphere

Explosive Dust Atmosphere

Explosive Gas and Vapor Atmosphere

MIE > 1000 mJ

A, B, C, D

B, C, D

C, D

1000 mJ > MIE > 3 mJ

B, C, D

B, C, D

C, D

MIE < 3 mJ

C, D

C, D

C, D


Product Inquiry